Types | Description | Functions | Order code |
Encoder feedback | PG speed controller option card | Phase A,B and Z pulse (differential pulse) inputs (RS-422) Pulse train position command input (RS-422) Pulse monitor output (RS-422) PG frequency range: 100 kHz max | 3G3AX-PG |
Communication option board | DeviceNet option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current ... through communications with the host controller | 3G3AX-RX-DRT |
PROFIBUS option card | 3G3AX-RX-PRT |
EtherCAT option card | 3G3AX-RX-ECT |
CompoNet option card | 3G3AX-RX-CRT |
MECHATROLINK-II option card | 3G3AX-RX-MRT |
I/O option | Extra input/output option card | 8 digital inputs, 8 digital outputs, 4 analog inputs, 1 analog output | 3G3AX-EIO21-ROE |
Max. input power kW | Order code |
Stand-alone | Kit |
Regenerative DC bus supply | Low harmonic filter | EMC filter |
30 | RFE-B3 30-400-50-230-A-RVE | RHF-RA 43-400-50-20-A-RVE | RFI-RA 12-RVE | RFE-B3 30-400-50-230-IF-RVE |
45 | RFE-B3 45-400-50-230-A-RVE | RHF-RA 72-400-50-20-A-RVE | RFE-B3 45-400-50-230-IF-RVE |
60 | RFE-B3 60-400-50-230-A-RVE | RHF-RA 86-400-50-20-A-RVE | RFI-RA 23-RVE | RFE-B3 60-400-50-230-IF-RVE |
80 | RFE-B3 80-400-50-230-A-RVE | RHF-RA 144-400-50-20-A-RVE | RFE-B3 80-400-50-230-IF-RVE |
100 | RFE-B3 100-400-50-230-A-RVE | RFI-RA X5-RVE | RFE-B3 100-400-50-230-IF-RVE |
125 | RFE-B3 125-400-50-230-A-RVE | RHF-RA 180-400-50-20-A-RVE | RFI-RA X6-RVE | RFE-B3 125-400-50-230-IF-RVE |
150 | RFE-B3 150-400-50-230-A-RVE | RHF-RA 217-400-50-20-A-RVE | RFE-B3 150-400-50-230-IF-RVE |
200 | RFE-B3 200-400-50-230-A-RVE | RHF-RA 304-400-50-20-A-RVE | RFE-B3 200-400-50-230-IF-RVE |
Low Duty applications (50%) | High Duty applications |
Max. regenerative power kW | Order code | Max. regenerative power kW | Order code |
8 | RLD-E0 8-400-50-0-A-RVE | 7 | RHD-B0 7-400-50-0-A-RVE |
12 | RLD-E0 12-400-50-0-A-RVE | 13 | RHD-B0 13-400-50-0-A-RVE |
16 | RLD-E0 16-400-50-0-A-RVE | 18 | RHD-B0 18-400-50-0-A-RVE |
20 | RLD-E0 20-400-50-0-A-RVE | 24 | RHD-B0 24-400-50-0-A-RVE |
24 | RLD-E0 24-400-50-0-A-RVE | 30 | RHD-B0 30-400-50-230-A-RVE |
32 | RLD-E0 32-400-50-0-A-RVE | 50 | RHD-B0 50-400-50-230-A-RVE |
40 | RLD-E0 40-400-50-0-A-RVE | 70 | RHD-B0 70-400-50-230-A-RVE |
48 | RLD-E0 48-400-50-0-A-RVE | 100 | RHD-B0 100-400-50-230-A-RVE |
58 | RLD-E0 58-400-50-0-A-RVE | 125 | RHD-B0 125-400-50-230-A-RVE |
80 | RLD-E0 80-400-50-0-A-RVE | 150 | RHD-B0 150-400-50-230-A-RVE |
95 | RLD-E0 95-400-50-0-A-RVE | |
116 | RLD-E0 116-400-50-0-A-RVE |
140 | RLD-E0 140-400-50-0-A-RVE |
170 | RLD-E0 170-400-50-230-A-RVE |
200 | RLD-E0 200-400-50-230-A-RVE |
Three-phase: 3G3RX-_ | A2004 | A2007 | A2015 | A2022 | A2037 | A2055 | A2075 | A2110 | A2150 | A2185 | A2220 | A2300 | A2370 | A2450 | A2550 |
Max. applicable motor 4P kW | at CT | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 |
at VT | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 |
Output characteristics | Inverter capacity kVA | 200 V | at CT | 1.0 | 1.7 | 2.5 | 3.6 | 5.7 | 8.3 | 11.0 | 15.9 | 22.1 | 26.3 | 32.9 | 41.9 | 50.2 | 63.0 | 76.2 |
at VT | 1.3 | 2.1 | 3.2 | 4.1 | 6.7 | 10.4 | 15.2 | 20.0 | 26.3 | 29.4 | 39.1 | 49.5 | 59.2 | 72.7 | 93.5 |
240 V | at CT | 1.2 | 2.0 | 3.1 | 4.3 | 6.8 | 9.9 | 13.3 | 19.1 | 26.6 | 31.5 | 39.4 | 50.2 | 60.2 | 75.6 | 91.4 |
at VT | 1,5 | 2.6 | 3.9 | 5.0 | 8.1 | 12.4 | 18.2 | 24.1 | 31.5 | 35.3 | 46.9 | 59.4 | 71.0 | 87.2 | 112.2 |
Rated output current (A) | at CT | 3.0 | 5.0 | 7.5 | 10.5 | 16.5 | 24 | 32 | 46 | 64 | 76 | 95 | 121 | 145 | 182 | 220 |
at VT | 3.7 | 6.3 | 9.4 | 12 | 19.6 | 30 | 44 | 58 | 73 | 85 | 113 | 140 | 169 | 210 | 270 |
Max. output voltage | Proportional to input voltage: 0 to 240 V |
Max. output frequency | 400 Hz |
Power supply | Rated input voltage and frequency | 3-phase 200 to 240 V 50/60 Hz |
Allowable voltage fluctuation | -15% to 10% |
Allowable frequency fluctuation | 5% |
Braking | Regenerative braking | Internal BRD circuit (external discharge resistor) | External regenerative braking unit |
Minimum connectable resistance | 50 | 50 | 35 | 35 | 35 | 16 | 10 | 10 | 7.5 | 7.5 | 5 |
Protective structure | IP20 |
Cooling method | Forced air cooling |
Three-phase: 3G3RX-_ | A4004 | A4007 | A4015 | A4022 | A4040 | A4055 | A4075 | A4110 | A4150 | A4185 | A4220 | A4300 | A4370 | A4450 | A4550 | B4750 | B4900 | B411K | B413K |
Max. applicable motor 4P kW | at CT | 0.4 | 0.75 | 1.5 | 2.2 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 |
at VT | 0.75 | 1.5 | 2.2 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 |
Output characteristics | Inverter capacity kVA | 400 V | at CT | 1.0 | 1.7 | 2.5 | 3.6 | 6.2 | 9.7 | 13.1 | 17.3 | 22.1 | 26.3 | 33.2 | 40.1 | 51.9 | 63.0 | 77.6 | 103.2 | 121.9 | 150.3 | 180.1 |
at VT | 1.3 | 2.1 | 3.3 | 4.6 | 7.7 | 11.0 | 15.2 | 20.9 | 25.6 | 30.4 | 39.4 | 48.4 | 58.8 | 72.7 | 93.5 | 110.8 | 135 | 159.3 | 200.9 |
480 V | at CT | 1.2 | 2.0 | 3.1 | 4.3 | 7.4 | 11.6 | 15.8 | 20.7 | 26.6 | 31.5 | 39.9 | 48.2 | 62.3 | 75.6 | 93.1 | 123.8 | 146.3 | 180.4 | 216.1 |
at VT | 1.5 | 2.5 | 4.0 | 5.5 | 9.2 | 13.3 | 18.2 | 24.1 | 30.7 | 36.5 | 47.3 | 58.1 | 70.6 | 87.2 | 112.2 | 133 | 162.1 | 191.2 | 241.1 |
Rated output current (A) | at CT | 1.5 | 2.5 | 3.8 | 5.3 | 9.0 | 14 | 19 | 25 | 32 | 38 | 48 | 58 | 75 | 91 | 112 | 149 | 176 | 217 | 260 |
at VT | 1.9 | 3.1 | 4.8 | 6.7 | 11.1 | 16 | 22 | 29 | 37 | 43 | 57 | 70 | 85 | 105 | 135 | 160 | 195 | 230 | 290 |
Max. output voltage | Proportional to input voltage: 0 to 480 V |
Max. output frequency | 400 Hz |
Power supply | Rated input voltage and frequency | 3-phase 380 to 480 V 50/60 Hz |
Allowable voltage fluctuation | -15% to 10% |
Allowable frequency fluctuation | 5% |
Braking | Regenerative braking | Internal BRD circuit (external discharge resistor) | External regenerative braking unit |
Minimum connectable resistance | 100 | 100 | 100 | 100 | 70 | 70 | 35 | 35 | 24 | 24 | 20 |
Protective structure | IP20 | IP00 |
Cooling method | Forced air cooling |